vEdge

Product Datasheet

PRODUCT PORTFOLIO

The vEdge routers are available in the following models:

  • 1vEdge-100: 100Mbps AES-256 throughput, with 5 fixed 10/100/1000 Mbps ports. Comes in 3 different flavors:
    • vEdge 100b: Ethernet only
    • vEdge 100m: Ethernet + integrated 2G/3G/4G modem
    • vEdge 100wm: Ethernet + integrated 2G/3G/4G modem + Wireless LAN
  • 2vEdge-1000:1 Gbps AES-256 throughput, with 8 ports of fixed GE SFP
  • 3vEdge-2000:10 Gbps AES-256 throughput, with 2 Pluggable Interface Modules

vEdge-100, vEdge-1000 and vEdge-2000 routers offer identical software functionality. The key differences between the platforms are in respect to throughput, redundancy in hardware components and port density. Some models of vEdge-100 routers offer additional functionality in the form of PoE, integrated GPS and integrated WiFi. Key hardware specifications for vEdge-100, vEdge-1000 and vEdge-2000 routers are listed in Table 1.

 

Table 1: Key hardware specifications of the vEdge routers

INTRODUCTION

The Viptela vEdge-100, vEdge-1000 and vEdge-2000 routers are hardware appliances that sit at the perimeter of a site, such as remote office, branch office, campus or a data center. They participate in establishing a secure virtual overlay network, Viptela Secure Extensible Network, over mix of any Wide Area Network transports. vEdge Routers provide essential features of routing, forwarding, security, encryption, QoS, policy and management.

ITEMvEdge-100vEdge-1000vEdge-2000
Services and Slot Density
Traffic ports5 x 10/100/1000 Mbps RJ-45 ports8 x 1 Gbps SFP4 x 1 Gbps SFP, 2 Pluggable Interface Module (PIM) slots. PIM Options: 2 x 10 Gbps SFP, 8 x 1 Gbps SFP
Embedded hardware-based crypto acceleration (IPSec)YesYesYes
Memory DDR3 ECC2 GB2 GB8 GB
SD card slot (external)N/AMaximum capacity supported 32 GBMaximum capacity supported 32 GB
NAND storage (internal)4 GB8 GB8 GB
External USB Host Port100b: N/A
100m & 100wm: 1 (USB 3.0 Type A)
2 (USB 3.0 Type A)2 (USB 3.0 Type A)
Power-over-Ethernet (PoE)100b: N/A
100m & 100wm: 1 port, 15.4W (802.3af)
N/AN/A
4G LTE100b: N/A
100m & 100wm: 1 Integrated
N/AN/A
Global Positioning System (GPS)Integrated with external antennaN/AN/A
USB console port1, Mini Type B (115.2 Kbps)1, Type B (115.2 Kbps)1, Type B (115.2 Kbps)
Serial console portN/A1, RJ-45 (115.2 Kbps)1, RJ-45 (115.2 Kbps)
Management Ethernet port (RJ-45 10/100/1000Mbps)N/A1, RJ-45 10/100/10001, RJ-45 10/100/1000
Power supply option100b: External AC-DC power adapter
100m: Internal fixed AC power adapter
External AC-DC power adapterHot-swappable Power Supply Units (PSUs)
Redundant power supply supportN/AYes1+1 active-active redundancy
Fans100b: N/A (fanless)
100m & 100wm: 1 fan, fixed
22, hot swappable
Power Specifications
AC input voltage90-264 Vrms (100-240V)90-264 Vrms (100-240V)90-264 Vrms (100-240V)
AC input line frequency47-63 Hz47-63 Hz47-63 Hz
Typical power consumption100b: 15W
100m & 100wm: 35W with PoE, 20W without PoE
28W125W
Physical Specifications
Rack height100b: 1 RU
100m & 100wm: 1RU Plus
1 RU1 RU
Chassis height100b: 1.75 in. (4.4 cm)
100m & 100wm: 1.8 in. (4.6 cm)
1.75 in. (4.4 cm)1.75 in. (4.4 cm)
Chassis width100b: 6.75 in. (17 cm)
100m & 100wm: 9.25 in. (23.5 cm)
7.5 in. (19 cm)Chassis only: 17.25 in. (43.82 cm)
Chassis with mounting brackets attached: 19 in. (48.2 cm)
Chassis depth100b: 5.5 in. (14 cm)
100m & 100wm: 5.75 in. (14.6 cm)
10 in. (25.4 cm)18.5 in. (47 cm)
Chassis weight1.75 lb (0.79 kg)3.55 lb (1.6 kg)Chassis only: 11 lb (5 kg)
Chassis with two power supplies installed: 15 lb (6.8 kg)
Airflow100b: N/A (fanless)
100m & 100wm: Top
Front to backFront to back
Rack-mount accessory kit 19 in (48.3 cm) EIA100b: Provided with the unit
100m & 100wm: Available and sold separately
Available and sold separatelyProvided with the unit
 Packaging Specifications
Package height3.58 in. (9.09 cm)8.5 in. (21.6 cm)8.5 in. (21.6 cm)
Package width100b: 7.75 in. (19.68 cm)
100m & 100wm: 10 in. (25.4 cm)
11.75 in. (29.84 cm)22 in. (55.88 cm)
Package depth13 in. (33 cm)16.5 in. (41.9 cm)23.5 in. (59.7 cm)
Operating Condition
Temperature0 to 40°C (32 to 104°F) at sea level (temperature de-rating of 1.5 deg C per 1000 feet of altitude applicable up to max of 10000 feet or 3000 m)0 to 40°C (32 to 104°F) at sea level (temperature de-rating of 1.5 deg C per 1000 feet of altitude applicable up to max of 10000 feet or 3000 m)0 to 40°C (32 to 104°F) at sea level (temperature de-rating of 1.5 deg C per 1000 feet of altitude applicable up to max of 10000 feet or 3000 m)
AltitudeMax 3000 m (10000 ft)Max 3000 m (10000 ft)Max 3000 m (10000 ft)
Humidity10 to 85% RH10 to 85% RH10 to 85% RH
Transportation/Storage Condition
Temperature-40 to 70°C (-40 to 158°F)-40 to 70°C (-40 to 158°F)-40 to 70°C (-40 to 158°F)
Humidity5 to 95%RH5 to 95%RH5 to 95%RH
Altitude4570 m (15000 ft)4570 m (15000 ft)4570 m (15000 ft)
Reliability
MTBF104K hours80K hours420K hours
Regulatory Compliance
SAFETYAS/NZS 60950-1AS/NZS 60950-1AS/NZS 60950-1
CAN/CSA 60950-1CAN/CSA 60950-1CAN/CSA 60950-1
CB-IEC60950-1CB-IEC60950-1CB-IEC60950-1
CE MarkingCE MarkingCE Marking
EN 60950-1EN 60950-1EN 60950-1
UL60950-1UL60950-1UL60950-1
EMC100b: AS/NZS CISPR22 Class A
100m: AS/NZS CISPR22 Class B
AS/NZS CISPR22 Class AAS/NZS CISPR22 Class A
EN 300 386EN 300 386EN 300 386
100b:EN 55022 Class A
100m: EN 55022 Class B
 EN 55022 Class A EN 55022 Class A
100b: FCC Class A
100m: FCC Class B
 FCC Class AFCC Class A
100b: ICES Class A
100m: ICES Class B
ICES Class AICES Class A
100b: VCCI Class A
100m: VCCI Class B
VCCI Class AVCCI Class A
ENVIRONMENTALROHS 6/6ROHSROHS

 

Table 2 below depicts key specifications for the 4G/LTE functionality on vEdge-100m

ITEMvEdge-100m
Hardware Components
LTE modem

Internal PCIe module

SIM card

1, Mini SIM (2FF)

Antenna type

MIMO, Dipole swivel

Antenna connectors

2, type F

Specifications and Features
User equipment implementation

3GPP, release 9 compliant

User equipment category

UE category 3

Maximum data transfer rates

Downlink: 100 Mbps

Uplink: 50 Mbps

Voice and SMS

No

Certifications

PTCRB, GCF

Table 2: 4G/LTE specifications of the vEdge-100m

Table 3 below depicts key specifications for Wireless LAN functionality on vEdge-100wm

ITEMvEdge-100wm
Specifications and Features
Frequency

2.4GHz OR 5GHz

Protocols

IEEE 802.11a/b/g/n/ac

Channel Bandwidth

20Mhz, 40Mhz or 80Mhz

SSIDs

Up to 4

Concurrent clients

50

Wireless Security and Authentication

WPA/WPA2 Personal or Enterprise, 802.11i

Wireless Encryption

AES/CCMP, TKIP encryption

WLAN antennas

Internal

Table 3: WLAN features

Table 4 below depicts 4G/LTE bands supported on vEdge-100 platforms

Region100m-VZ100m-AT100m-NA100m-GB100m-NT

LTE Bands

4 (AWS 1700MHz/2100Hz),
13 (700MHz)
2 (1900MHz),
4 (AWS 1700Hz/2100Hz),
5 (850MHz),
17 (700MHz)
2 (1900MHz),
4 (AWS 1700MHz/2100MHz),
5 (850MHz),
13 (700MHz),
17 (700MHz),
25 (1900MHz)
1 (2100MHz),
3 (1800MHz),
7 (2600MHz),
8 (900MHz),
20 (800MHz)
1 (2100MHz),
19 (800MHz),
21 (1500MHz)

Australia

×

×

×

×

Europe

×

×

×

×

Middle East

×

×

×

×

Latin America

and Asia Pacific

×

×

×

×

United States

VerizonAT&T

×

×

Canada

×

×

×

×

×

Japan

×

×

×

NTT Docomo

Table 4: 4G/LTE bands supported on vEdge-100m

Table 5 depicts 2G and 3G bands supported on vEdge-100 platforms

Technology100m-VZ100m-AT100m-NA100m-GB100m-NT
UMTS/HSPA+

×

2 (1900MHz),
4 (AWS1700/2100MHz),
5 (850Mhz)
A1 (2100MHz),
2 (1900MHz),
2 (1900MHz),
5 (850MHz),
8 (900MHz)
1(2100MHz),
2 (1900MHz),
5 (850MHz),
8 (900MHz)
1(2100MHz),
5 (850MHz),
6 (800MHz),
19 (850MHz)
GPRS/EDGE

×

GSM 850 (850MHz),
EGSM 900 (900MHz),
DCS 1800 (1800MHz),
PCS 1900 (1900MHz)
 
GSM 850 (850MHz),
EGSM 900 (900MHz),
DCS 1800 (1800MHz),
PCS 1900 (1900MHz)
GSM 850 (850MHz),
EGSM 900 (900MHz),
DCS 1800 (1800MHz),
PCS 1900 (1900MHz)
 
GSM 850 (850MHz),
EGSM 900 (900MHz),
DCS 1800 (1800MHz),
PCS 1900 (1900MHz)
 
CDMA
EVDO Release 0,
EVDO
Release A
 
BC0 (Cellular 800 MHz),
BC1 (PCS 1900 MHz),
BC10 (Secondary 800 MHz)
 

×

×

×

×

Table 5: 2G and 3G bands on vEdge-100m

SOFTWARE CAPABILITIES

The vEdge routers leverage standards based features for the LAN (Service) and WAN (transport) side of the network. Key software capabilities of the vEdge-100, vEdge-1000 and vEdge-2000 routers are listed in Table 5.

CATEGORYFEATURES
AAA

TACACS+, RADIUS, local, Role Based Access Control

Routing

OSPF, eBGP, iBGP, static, connected, OMP

Bridging

802.1Q, native VLAN, bridge domains, IRB, host-mode bridging

Security

Zero-trust, whitelisting, Tamper Proof Module, DTLS/TLS, IPSec, ESP-256-CBC, AH, HMAC-SHA1, DDOS protection, control plane protection, NAT traversal

Forwarding and QoS Classification, prioritization, low latency queuing, remarking, shaping, scheduling, policing, mirroring, NAT/PAT
Multicast

IGMP v1/v2, PIM, Auto-RP, scale-out traffic replication

Policy

Route policies, App Aware Routing, control policy, data policy, ACL policy, VPN membership policy, service advertisement and insertion policy

Location Services

Geo-location (vEdge-100m)

Cellular

Integrated 4G/LTE modem (vEdge 100m), circuit of last resort

Mobility

WiFi 802.11 a/b/g/n/ac, WPA2- Enterprise, WPA2-Personal, MAC Filtering, 8 SSIDs per-radio, 802.11i security enhancement and 802.11e QoS, wireless intrusion detection and protection

System and Network Services

IPv4, SNMP, NTP, DNS client, DHCP client, DHCP server, DHCP relay, config archival, Syslog, SSH, SCP, NAT/PAT, Cflowd v10 IPFIX export

Configuration and Monitoring

Netconf over SSH, CLI, REST (vManage), Linux shell

Out-of-band Management

Management port (vEdge-1000, vEdge-2000), Serial console port (vEdge-1000, vEdge-2000), USB console port

ORDERING INFORMATION

Ordering information for vEdge-100, vEdge-1000 and vEdge-2000 routers is listed in Table 6.

SKUSKU DESCRIPTION
vEdge-100b-AC

vEdge-100 AC chassis with 5 Ethernet ports, rack mount kit and cables

vEdge-100m-AC

vEdge-100 AC chassis with single 4G/LTE SIM, integrated power supply, 5 Ethernet ports and cables

vEdge-1000-AC

vEdge-1000 AC base chassis with 8x1GE fixed ports, dual AC power adapters and cables

vEdge-2000-AC

vEdge-2000 AC base chassis with 4x1GE fixed ports and dual Pluggable Interface Module slots, dual AC power supplies, rack mount kit and cables

PIM-8x1GE-SFP

8x 1GE SFP Pluggable Interface Module for vEdge-2000

PIM-2x10GE-SFP+

2x 10GE SFP Pluggable Interface Module for vEdge-2000

Table 6: Ordering information for vEdge routers

FOR MORE INFORMATION ON THE VIPTELA SOLUTION AND HOW IT CAN HELP YOUR NETWORK, PLEASE CONTACT SALES@VIPTELA.COM

Viptela Inc.,1732 N.First St., Suite 600
San Jose, CA 95112, USA
Tel: +1(800) 525-5033
www.viptela.com

Copyright © 2016 Viptela, Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws. Viptela, Inc products are covered by one or more patents available upon request. Viptela, Inc. is a registered trademark or trademark of Viptela, Inc. in the United States and/or other jurisdictions. All other marks and names mentioned herein may be trademarks of their respective companies.